Test Range
The radiation harassment RE mainly refers to the disturbance caused by the energy in the form of electromagnetic wave from the source to the space, and the phenomenon of the propagation of space and the equipment in the surrounding environment.
The 966 Full-Dynamic Room Electromagnetic Compatibility (EMC) laboratory has a 3-meter anechoic chamber with full/semi-acoustic darkroom conversion. The test system for the darkroom in the laboratory is provided by the well-known German R/S company and has a full set of EMC test software. For mobile phone customers, we also provide mobile phone stray test equipment and corresponding supporting software.
The complete EMS equipment in the laboratory is provided by HTEC manufacturers with stable performance and accurate data.
The current testing capabilities and test criteria are:
★EMI Lab:
(1) Radiation Disturbance Test (RE)---Test Standard: EN55032
(2) Conducted Disturbance Test (CE)---Test Standard: EN55032
(3) Harmonic current test (Harmonic) --- Test standard: IEC 61000-3-2
(4) Voltage change and flicker test (Flicker)---Test standard: IEC 61000-3-3
★EMS Lab:
(1) Electrostatic discharge immunity test (ESD)---Test standard: IEC 61000-4-2
(2) Radio frequency electromagnetic field radiation immunity (RS)---Testing standard: IEC 61000-4-3
(3) Conducted disturbance immunity (CS) induced by RF field---Testing standard: IEC 61000-4-6
(4) Electrical fast transient burst immunity test (EFT)---test standard: IEC 61000-4-4
(5) Surge (shock) immunity (SURGE)---Testing standard: IEC 61000-4-5
(6) Voltage dip, short-term interruption and voltage change immunity test (DIP)---test standard: IEC 61000-4-11
(7) Power Frequency Magnetic Field Immunity Test (PFMF)---Test Standard: IEC 61000-4-8
Zhongjian Testing can provide technical services such as testing, problem rectification and certification for enterprise products. Solve the relevant technical problems after the product is designed, ensure that the corresponding electromagnetic compatibility standards are met, and obtain the certification as soon as possible.
Zhongjian testing experts have many years of experience in EMC, safety and lightning protection in professional laboratories, and are familiar with the increased device cost in the countermeasure process. They can provide fast, efficient and low-cost rectification solutions for enterprise products in a short period of time. The cost of production is low, and the interests of customer customers are improved.
★ Rectification service
Electromagnetic interference (EMI) problem rectification service
Electromagnetic anti-jamming (EMS) problem rectification service
Single Board PCB EMC Design Service
Engineering application interference EMI problem rectification service
Engineering application anti-interference EMS problem rectification service
Product EMC Testing Service
Product EMC Certification Service
★ Rectification
966 full anechoic chambers from the perspective of product system, through detailed analysis of product schematics, PCB, structure, to solve the EMC problem of the product from the source, to ensure that enterprises provide fast, efficient, low-cost, mass production rectification program To enhance the interests of customers.